which of the following describes the cushing reflex?
Select Page

wanting to buy a battery backup system for the M 53 . These accessories are required to properly setup/install this product. Thanks. All is operating well - Leading up to a question, I think I am getting some water hammer. I installed the Zoeller M53 with the recommended 1 1/2" Zoeller check valve. At this point, you could attach the check valve and then complete your discharge configuration. My pit is 15" across by 24" deep. My concern is that it will be going off even more often if I change to a submersible style pump because it sits lower in the pit. Unlike Born, raised, and built in the U.S.A., Goulds Water Technology is an American m You'll hardly think about your sump pump until it's too late. Please give our experts up to two business days to respond. This is completely normal. live 1 bloock from river i get water from that and ground water. If water has seeped into the switch housing, this would certainly compromise the performance and safety of the pump and I would highly recommend replacing the pump. If I raise it 6 in. Can i raise the pump in the sump 6 inches or so and therefore pump more water per cycle. What am I expected to put between the pump body and the bottom clamp of this check valve? 2) what is the recommended location for the new check valve? 8 in. Your only option would be to either replace the pump with a different type of switch, possibly a tether or electronic switch or by rigging the switch on your M53 to stay on and then add another "piggyback" style switch. Zoeller Complete Cover Assembly & Switch Kit For M53 Sump Pump, Cast Iron Switch Case, Motor & Pump Housing. I have a Zoeller M53 1/3 hp sump pump. Is the 1 inch pipe OK, or is it necessary to change to 1 1/2 inch pipes? The 6.5 amps you mention are the running amps. So if the M53 worked well for you and you never came close to flooding, I would suggest keeping that 1/3HP pump in place. Thanks, The "weep" hole as it is called should always be drilled in your discharge pipe to prevent an airlock. Even with this air relief hole in the pump, it's still highly recommended that you drill a "weep" hole in your discharge pipe. What kind of draw (startup and normal operation) should I include in my calculations for sizing the generator. every hour for maybe 5 seconds max. That being said, all pumps should last a good 5-7 years or more providing they are installed properly. The relief hole in the pump will help prevent any air lock within the pump. I have a Zoeller M53 in a basement sump 24 in. I have a M53-D Zoeller pump that is about 10yrs old.I was told by my home builder that it was rated to pump vertical up to 10ft.is this true?I have miss placed my owners manual and now the switch is bad so that the pump runs constant till it over heats,is that do to pumping vertical for 10yrs out of my basement for a washer?By the way it has been a great pump and will never own anything but a Zoeller for the rest of my time.Thank you. below underside of concrete floor when the float activates. I have cleaned the pump, well and float. When it rains, my pit fills up very quickly and the pump goes every 2-3 minutes. I currently have a 1/3HP pedestal pump discharging through a 1-1/4" pipe. Regarding the noise concern, there should not be any difference as long as the pump is installed properly. the water table would still be approx. The trapped air prevents the impeller from drawing in enough fluid to open the check valve to allow discharge. The switch on the Zoeller M53 has about a 4 1/4" differential so by raising your pump in your basin, you will effect the level at which the pump will activate, however you will NOT effect how much water is pumped out. ", Designed for rapid heat dissipation and extended life, Offers years of reliable, trouble-free operation, Oil-filled and hermetically sealed to prevent overheating, Assures maximum protection for extended pump life, No screen to interfere with flowing debris, Entire unit is pressure tested after assembly. I need to buy a generator, so I'm trying to determine what size. Located in NW Ohio and water table is fairly high. The 1/3HP model is just over 10 inches tall and the 1/2HP model is just over 12 inches tall. Is any maintenance required on the M53 pump? I see there are two white plugs on the pump and I'm wondering if oil needs to checked or added periodically or any other type of maintenance is needed. Do you still need to drill an air relief hole in your pipe if this pump has an air relief hole? That being said, you can make the call on weather you would like to replace the pump or the. There is usually a brass tag mounted on the top side of the pump between the the power cord relief and the float switch arm that will give you the model number and date code in addition to the voltage and amps. Can you please assist me. Some are more efficient than others. It has been running well, but now it will not come on. Reducing it further will only create more backpressure on the pump which will reduce the pump life, not to mention the reduction in pumping capacity that you would realize. Please note however, that you will also need protection in the event of a power outage. Zoeller pumps are known to last but are also known for some switch problems. The beach house we purchased sits on stilts with all concrete drive-thru underneath. zoeller fnpt ferguson An air relief hole in the base portion of the pump to help prevent air lock within the pump. One of the advantages to pedestal pumps is that you have the ability to adjust the float switch to allow the pump to evacuate more water out of your pit per cycle, thereby reducing the number of cycles per hour. We are based in Bolingbrook, Illinois and only operate out of this single location. The minimum sump basin size relates to the minimum size of your sump basin or pit, that a specific pump will safely operate in. It is designed to handle a maximum of 15 feet of vertical lift. All Rights Reserved\"}","expertJSON":{"imageURL":"https:\/\/www.powerequipmentdirect.com\/images\/experts\/expert-main-10.png","href":"\/sump-pump-product-expert.php","title":"Contact Jim @ Sump Pumps Direct","expertName":"Jim","expertTitle":"Sump Pump Expert"},"bbbJSON":{"imageURL":"https:\/\/www.powerequipmentdirect.com\/images\/badge-bbb.png","imageAlt":"Better Business Bureau\u00ae","href":"http:\/\/www.bbb.org\/chicago\/business-reviews\/industrial-equipment-and-supplies\/power-equipment-direct-in-bolingbrook-il-57001088","title":"Sump Pumps Direct - A+ Rating - Better Business Bureau\u00ae"},"zipCode":null,"phoneNumber":"888-455-4682","loginToken":"bc937ff5da63b36ffbaeaf02c81b7fd5d7d9f37afcaec14869a97f2b9e909a98","iterable":"e4b27e68b9c84fbb940829a0a9ee29d7","newNav":true}. Typically, the pump should give you about 5-7 years of life in a standard sump application. When in doubt, you should contact a licensed electrician in your area. Zoeller 1050001 13 HP M53 Remote SinkDrain Pump System w Vertical Float Switch The M53 is the most popular 1/3 HP Zoeller pump, so it would probably be safe to say that's the model. That would tell you exactly what size generator you would need to run both appliances at the same time. Any suggestions? In that case, your best defense is a higher output. But I was wondering does this need more than a 15 amp outlet, due to start up amps? zoeller 115v effluent Amps times volts give you watts. The starting amps for the M53 are 25.9. Other than that, both pumps are the same. None, whatsoever. I want to replace it and was looking at this pump because my existing one is old and noisy. What size generator would I need to run both of these during a storm? You don't want to just install a 3/4HP or 1HP pump just for the sake of it. Please review all product specs prior to purchase. Is there a difference between the m53-d mighty mate and the m53. i want 2sump pumps 1 higher tha other. deep. The switch is the most common reason for failure and can be replaced, though it is a bit involved on the "M" Series models. Without knowing more specifics like the water table, area of the country you live in, actual square footage of your basement, etc., it really is difficult to answer. It leaves dirt all across our front yard and underneath our house, both of which are concrete. Unfortunately, I would not have the answer to that question. Would this pump be suitable for a 12' x 12' basement? My basement is 104' and currently takes in approximately 3" of water when there is a hard rain. I would like to buy a generator to run that sump pump plus my icebox which takes 6.5 amps/115 volts. Note, in hurricane Irene my pump was going off every minute. I am getting a portable generator and want to include my zoeller m53-d pump to be one of the items supported by the generator. There is no info on tag that is attached the plug wire. You might try looking at our listing of manufacturer contact. Pedestal sump pumps sit on a pedestal that keeps them out of the water. Thank you, This float has limited movement up and down and side to side, giving it less freedom of movement and less of a chance to get stuck as a tethered float would. After a big rain, it is not uncommon for the flow of water coming in to be 2-3" deep. You want to pay very close attention to these requirements as they will insure a longer pump life. It's always recommended that you drill a weep hole in your PVC discharge pipe with a bottom suction pump. How To Pick The Perfect Pedestal Sump Pump. Since M53 have a built in air relief hole do I need to drill a hole into my PVC pipe? Thank you for your interest in Sump Pumps Direct. I think only only one model m53 can be ordered through Sears. We do offer the. These check valves should help reduce the "thumping" sound if they don't eliminate it all together. I don't want it to have to run more often then it does now. Will that be the case? The pump pumps up 1.5' then 25'to the 4" drain line. I mounted the check valve about 5' above the base of the pump, about 2 1/2' above the check valve the pipe makes a 90 degree turn. IF that M53 had difficulty with demand at any time however, then I would suggest increasing to the 1/2HP model M98. The 2" discharge WOULD require an adapter for either pump discharge, but should help. I have heard of this pumps lasting for 10, 15, 20 and even up to 30 years. That really depends on the pump. IF you have more water than sand, that M53 will handle it. I would suggest increasing the discharge piping from 1-1/4" to 1-1/2" or even 2". the pump rests on the bottom and the float activates Approx. Chances are that the switch has failed and needs to be replaced, which is a common occurrence. You might try to brace and/or pad any area of the discharge pipe that may be coming in direct contact with any walls, ceilings or joists to try to reduce the vibration that is being caused by the sudden reversal of the water flow once that pump switches off and that check valve slams shut. for safty, You are describing a fairly common application. This pump is approx 7 years old, seems to work fine , do I need to consider replacing and with what. Hi there, I'm planning on using this pump and a Jackel sump basin ( or something like that) to move water from a "lake" in my diveway, about 50' horizontally to a flower bed. While the Zoeller pumps are one of the better pumps out there, they are not very efficient. The zoeller M53 unit is approximately 3 years old. Is there any way for me to tell whether it is a 1/3 or 1/2 hp model? Bottom line, this pump is not moving water out fast enough to keep the water from going under the house and into the pool. As the water level rises so does the float which, at some point, it will trigger the switch to turn the pump on. Yes, you can, but you need to purchase it direct from Zoeller. It is at least 7 years old. HELP!! That said, I have heard of them lasting 10, 15 and 25+ years in some cases. Two questions: 1) the current set up uses 1 inch PVC discharge pipes - up about 8 feet and then horizontal for another 15 feet until exiting the house. For example, the 1/3HP Basement Watchdog model. Product Video Disclaimer: "PED is not responsible for any variances from the product in this video and the item you purchase. Your submission has been sent successfully. What is the model # I should buy. A lot of homeowners will install 2 sump pumps in their sump basin for this type of situation. All Rights Reserved\"}","checkoutMiscLinkJSON":"{\"Privacy Policy\":{\"href\":\"privacy.php\",\"title\":\"Privacy Policy\"},\"Terms of Use\":{\"href\":\"terms-of-use.php\",\"title\":\"Terms of Use\"},\"copyright\":\" 2022 Power Equipment Direct. The pump starts smooth but when it switches off it rattles the pipes. When using the formula of amps X volts = watts, you would need a minimum 1152 running watts and 3108 starting watts to operate your pump. What locations in Anchorge sells your product. Do I have to replace the pump? I installed according to directions.